Blog · 3 min read
Watermaker pre-departure checklist
March 5, 2025
Watermaker problems are much easier to fix at the dock than offshore. Run this quick check a few days before you leave — that gives time to sort parts if something's off.
Checklist
- Change all pre-filters and inspect sea strainer
- Run the system for at least 30 minutes and log pressure, flow, and salinity
- Confirm automatic fresh-water flush cycles correctly
- Inspect for oil weeping around the high-pressure pump
- Check for any raw-water leaks in the low-pressure loop
- Carry spare pre-filters, a spare set of pump seals, and pickling chemical
If anything looks off, get it looked at while you're still at the dock.